NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 607
Priority Paging
P-30
Service Conditions (cont’d)
12.
Forced release of a Paging Trunk is processed so that the station connected with that specific Paging Trunk
is regarded as having released. Therefore, after the forced release of the paging trunk, the state of the
station is as follows:
a.) if there is a call on hold:
Dial Tone Connection
b.) if there is no call on hold:
Recall (Calling Only)
(Answering - Non-Delay)
Dial Tone Connection (Answering - Delay basis)
(Paging Transfer)
13.
Going on-hook by the station after dial tone connection will result in Recall. As the Paging Memory
becomes free after this Recall, a PRIORITY PAGING call can be originated.
14.
Forced clearance of the Paging Memory is processed as a time-out of a paging call awaiting answer.
Therefore, after the forced Paging Memory clearance, the state of the station is as follows:
a.) if there is no call on hold:
Same as before clearance
b.) if there is a call on hold:
Recall
Note
Note:
If a Recall cannot be made because of a busy line, etc., the Paging Memory is not cleared until the line is
released and Recall is possible.
15.
Both the COT card and the TLT card can be used as the paging trunk.
16.
Loop signaling is the recommended signaling type.
Programming
STEP 1:
ASYD
- System Data 1, Index 73, bits 0 & 1. For PAGING function only, assign data “00”.
STEP 2:
ARTD
- Assign the Paging route as shown below:
RT: 1
1-OSGS
:2
2-ONSG
:3
4-INSG
:3
5-TF
:1
6-TCL
:8
7-L/T
:1
8-RLP
:2
15-LSG
:0/1
44-PRV
:1
STEP 3:
ATRK
- Assign the LEN, Paging Trunk Route Number, Trunk Number, and Tenant Number.
STEP 4:
MBTK
- Assign the Make Idle status to the Paging trunks.
STEP 5:
ANPD
- Assign a level for trunk access. Assign Connection Indexes, CI = N, H; Normal (N), and
Hooking (H). Assign the Number of Necessary Digits according to a predetermined numbering plan.
Busy Lamp Field is not activated.
STEP 6:
ASPA
- Assign the PAGE ACCESS code. Type of Service, SRV = OGC (Outgoing Call). Assign the
proper route number associated with this access code. Assign Connection Indexes, CI = N, H; Normal
(N) and Hooking (H).
STEP 7:
ARSC
- Assign to the station that is allowed access to paging trunks a Route Restriction Class (RSC)
that is allowed these routes in Route Restriction Indexes (RRI) 2 & 3.
STEP 8:
ASFC
- Allow SFI = 57, Priority Page, to the Service Feature Class of stations allowed this feature.
STEP 9:
ASPA
- Assign an access code for SRV = SSC (Service Code), SID = 40 (Priority Page).
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...