NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 619
Rotary Dial Calling
R-5
R-5
Rotary Dial Calling
General Description
This feature permits users to originate calls over rotary or push-button lines using Rotary Dial telephones.
Operating Procedure
Users dial rotary telephones in the normal fashion.
Service Conditions
1.
Rotary dial telephones installed should be industry standard 10pps instruments.
2.
Pushbutton instruments may be used in conjunction with ROTARY DIAL CALLING.
3.
It is possible to provide only the ATTENDANT CONSOLE [A-3] with push-button calling, while all other
stations are assigned ROTARY DIAL CALLING. Refer to PUSHBUTTON CALLING - ATTENDANT
ONLY
for further details.
4.
If ROTARY DIAL CALLING is assigned to a line, only Rotary Dial sets can be used on that line.
5.
POWER FAILURE TRANSFER [P-3]: Rotary dial telephones must be used as POWER FAILURE
TRANSFER [P-3] stations if the serving central office facility is not arranged for pushbutton calling. A
ground start button on the station set is required if the central office facility uses ground start signaling.
Interactions
1.
Rotary-to-Pushbutton conversion may be accomplished by assigning data “2” for CDN 2:ONSG in
ARTD; or assigning data “1” in ASYD, System Data 2, Index 1, Bit 0, and assigning CDN 2:ONSG as
data “3”, DP/PB.
2.
See UNIVERSAL SENDER
for sender programming
3.
ROTARY DIAL CALLING may be accomplished via an extension of PUSH-BUTTON CALLING [P-4]
if a Telephone Equipment Class of 3 has been programmed.
4.
The * or # symbols cannot be used as feature activation codes with ROTARY DIAL CALLING.
5.
The PBX Originating Registers Trunks (Route 902) can accept both rotary and push-button signals (a
separate register group is not required).
Programming
STEP 1:
ASYD
- System Data 2, Index 2, Bit 0. Sender signal for station is DP only/PB? 0/1: DP only/PB only.
This Bit is operative only when ARTD CDN 2:ONSG is assigned as data “3”, DP/PB. Assign data “0”.
STEP 2:
ASDT
- Assign single-line stations a Telephone Equipment Class (TEC) as rotary (DP) TEC = 1; or
dial pulse/push-button (DP/PB), TEC = 3. D
term
sets are always push-button.
STEP 3:
ATRK
- Assign Originating Register Trunks (ORT) to the system in a quantity calculated from
expected traffic. Registers are located on levels 0-3 of any 8RST circuit card.
Also, senders must be assigned to the system in a quantity calculated from expected traffic. Senders
are located on levels 4-7 of any 8RST circuit card.
RT:
Route Number
Trunk Route Number
Intra-office Route Number (901-931)
901 - ATT 912 - ORT for ATT
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...