General Description
This feature allows the D
term
to display calling party’s number and/or name on the LCD when a call from analog
C.O. line is terminated. In addition, the calling number can be output as a part of SMDR information.
Caller ID information can be displayed on an analog telephone with a display device or the display of a D
term
.
Operating Procedure
No manual operation is required.
Service Conditions
1.
This service is available when an incoming call from C.O. line is terminated directly to a station.
2.
First ringing pattern for this service is 2-seconds ON and 4-seconds OFF. After that, ringing pattern
assigned by system data is applied.
3.
The calling numbers received by using this feature or current MF/ISDN feature may be output to the
SMDR expanded area.
4.
A calling number cannot be received during conversation.
5.
The calling numbers which may be added to SMDR output are the dial code only. The calling name is not
added.
6.
This service is not provided for the Attendant Console.
7.
This service is not applied to SAVE AND REPEAT [S-24D] service. The calling number received may
not be saved.
8.
A maximum of 256 calls per LP are available at the same time.
9.
When an incoming call is sent as a test, the LCD does not display both the number and the name.
10.
Display conditions are shown below. Also, the ID display of ISDN service has the same conditions.
a.) It is assigned by system data in which display of the calling number or name has priority on
termination. When the calling name has priority, the LCD displays:
When the calling number has priority, the LCD displays:
* 1 - In ISDN service, the sub-address is displayed. When the D
term
does not receive the data
pertaining to the sub-address, nothing is displayed.
* 2 - If the prior display is not assigned by system data, the other is displayed.
b.) The calling number and name may be exchanged by pressing the feature key, according to the
following conditions:
•
When my line is prime line, displays may be exchanged during termination or conversation.
•
When my line is not the prime line, displays may be exchanged only during conversation.
c.) When the received numbers of a calling number and calling name exceed the display field, the
decision to put the digits to the right or left may be chosen in system data. An “*” is indicated on
the exceeded digit position.
(Time Display)
Calling Number XXXXXXXX
Caling Name
* 1
* 2
(Time Display)
Calling Name XXXXXXXX
Caling Number
* 1
* 2
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...