NEAX2400 IPX Feature Programming Manual
Page 140
NDA-24297, Issue 1
C-6
Call Hold
Interactions (cont’d)
14.
Calls remain on CALL HOLD until the controlling station replaces the handset, causing the held call to
ringback. If the controlling station does not answer the recall within the preset time-out interval (System
Data 1, Index 139), the connection is released.
Programming
STEP 1:
ASYD
- System Data 1, Index 139. No Answer Timer for CALL HOLD. (When Station A places
Station B on HOLD, and hangs up, Station A will ring after a preset period of time has elapsed. If
Station A does not answer, then Station B goes from ringback tone to reorder tone.)
System Data 2, Index 1, Bits 0 & 1. CONSULTATION HOLD [C-17] allowed or denied. 00: Denied;
Originating and Terminating Calls allowed, Tandem Calls Denied; 11: All calls allowed.
STEP 2:
ANPD
- Reserve a number level for feature access and cancel. Assign for Normal (N), Hooking (H),
and Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 3:
ASPA
- Assign an access code for CALL HOLD, SID = 1 for Connection Status Index (CI) of
Hooking (H).
STEP 4:
ASFC
- Assign a Service Feature Class that allows SFI = 10 to stations that are allowed CALL
HOLD.
STEP 5:
AKYD
- Optional. Assign CALL HOLD to a programmable Line/Feature key. Assign
Type:Function:CALL HOLD [10]. (The operation of TRANSFER key and access code is also
available). Type:Function:FLASH BUTTON [21].
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note 1
STEP 1:
ANPDL
- Reserve a number level for feature access and cancel. Assign for Normal (N), Hooking (H),
and Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 2:
ASPAL
- Assign an access code for CALL HOLD, SID = 1 for Connection Status Index (CI) of
Hooking (H).
Note 1:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
Note 2:
System timers may be set on a network basis in ASYDN.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...