NEAX2400 IPX Feature Programming Manual
Page 588
NDA-24297, Issue 1
P-9
Priority Call
Interactions (cont’d)
3.
If the destination of a Priority Call is the Attendant Console, the Priority Call does not transfer to the
ATTENDANT NIGHT TRANSFER [A-19] station when the system goes into Night mode.
4.
A PRIORITY CALL will not be forwarded to outside.
Programming
STEP 1:
ASYD
- System Data 1, Index 168, Bit 6. Where will Priority Call terminate? 0/1: Attendant Console/
Station. If Attendant Console (0), go to Step 2, AAKP command.
System Data 2, Indexes 8 & 9. If the call will terminate to the Attendant Console, assign if the call will
be pegged for CALL WAITING LAMP [C-13].
STEP 2:
AAKP
- Assignment of Attendant Console Key Pattern. The ATN: Attendant Number (TRK No. for
RTE 901); KYN = 1-6, and FUNC = 3, Priority Call 1; FUNC = 4, Priority Call 2; FUNC = 5, Priority
Call 3. This command is not required if the Priority Call terminates at a station.
STEP 3:
ANPD
- Reserve a Numbering Plan level for feature access. Assign Connection Indexes (CI), CI = N,
H, B; Normal (N), Hooking (H), and Busy (B) (applicable to any feature assigned to this level). Assign
NND in accordance with the predetermined numbering plan.
STEP 4:
ASPA
- For SRV = SSC (Service Code) SID = 37, Priority Call 1; SID = 38, Priority Call 2; SID = 39,
Priority Call 3; assign the access code. Assign for CI of Normal (N).
STEP 5:
ASID
- This command defines the purpose of this Special Incoming Group and is used in conjunction
with the ASGD command. Assign the following:
TN:
Tenant Number
F:
Function Number (0-7)
4:
Priority Call 1
5:
Priority Call 2
6:
Priority Call 3
GN:
Group Number (1-7),
S/A:
Special Incoming Equipment
S:
Station
A:
Attendant Console
SSTN: Special Station Number
STEP 6:
ASGD
- This command defines the stations belonging to the Special Incoming Group. When the point
of termination is a station, assign the following:
TN:
Tenant Number
STN:
Station Number
F:
Function Number (0-7)
4:
Priority Call 1
5:
Priority Call 2
6:
Priority Call 3
GN:
Group Number (1-7)
STEP 7:
ASFC
- Service Feature Index (SFI) 54-Priority Call 1. SFI 55-Priority Call 2. SFI 56-Priority Call 3.
Assign a Service Feature Class to stations that allow one or all of the SFIs above, depending on system
configuration.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...