NEAX2400 IPX Feature Programming Manual
Page 678
NDA-24297, Issue 1
S-10
Station Message Detail Recording (SMDR)
Service Conditions (cont’d)
4.
Assign Fusion Point Code (FPC) of new-Center Node to all node including ex-Center Node by using
ASYDL command System Data 1 Index 577.
Interactions
1.
If LCR(S) is provided, the LCR(S) access code is listed in ARNP. If an outgoing route is not used in
LCR(S), then list the OGCA access code in ARNP.
2.
To test SMDR output, it is recommended that a serial printer or breakout box be used to determine if the
system is sending data.
3.
CALL TRANSFER-ALL CALLS [C-11]: Either the first station, last station, or split billing is allowed
with SMDR. Split billing provides a separate call record for both before and after a call transfer.
4.
ATTENDANT CAMP-ON WITH TONE INDICATION [A-1]: The called station number is recorded for
incoming C.O. calls via the Attendant Console (RRI 2 of ARSC). To record the time a destination station
is on a call, split billing or last station billing is required. With split billing, the time the Attendant Console
is on the call is separated from the time the destination station is on the call. For last station billing, the
destination station is charged with the entire time of connection.
5.
LEAST-COST ROUTING-3/6-DIGIT [L-5]: SMDR will record the digits sent rather than the digits
dialed.
6.
The destination station is recorded on SMDR for the following features:
CALL FORWARDING
[C-2, 3, 5]
CALL PICKUP
[C-7, 30]
7.
CALL FORWARDING-INTERCEPT [C-25]: An incoming trunk call responds to Call Forwarding-
Intercept to the Attendant Console. SMDR records the call as if it is a direct call to the Attendant Console.
8.
NIGHT CONNECTION-FIXED/FLEXIBLE [N-1, 2]: Calls terminated to these stations are recorded on
SMDR.
9.
OUTGOING TRUNK QUEUING [O-2]: SMDR records the outgoing call when the system recalls the
user and the digits are sent, not when the trunk is queued.
10.
REMOTE ACCESS TO SYSTEM [R-2]: The incoming route and trunk number is recorded as the calling
party. If FORCED ACCOUNT CODE [F-7] is used, it will be recorded on SMDR. REMOTE ACCESS
TO SYSTEM via a DID will not record FORCED ACCOUNT CODE on SMDR.
11.
TRUNK-TO-TRUNK CONNECTION [T-10] and TIE LINE ACCESS [T-3]: SMDR records an
incoming TIE Line that uses TRUNK-TO-TRUNK CONNECTION to make an outgoing call. The TIE
Line route and trunk number is recorded as the calling party. The outgoing route is programmed for SMDR
in ARTD, not the incoming TIE Line route.
12.
CALL WAITING-TERMINATING [C-12]: SMDR will begin recording the call when the call is
answered, not when a Call Waiting Tone is heard.
Programming
STEP 1:
ASYD
- System Data 1, Index 20, Bit 7. Charging to a call transferred by CALL FORWARDING-
OUTSIDE Service 0/1: Charging is made to the caller of the transferred call / charging is made to the
station that has set CALL FORWARDING-OUTSIDE service. System Data 1, Index 32. Assign data
86H. Bit 7 enables SMDR service, Bit 2 will record the route taken, and Bit 1 records tenant
information.
Optional assignments may include Bit 5 and Bit 6.
System Data 1, Index 32, Bit 5. Is the Route Access code recorded? 0/1: No/Yes.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...