NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 455
LDN Night Connection
L-28
Interactions (cont’d)
5.
An incoming DID call will ring at the Night transfer destination station if CALL FORWARDING-DON’T
ANSWER [C-3] is set to the Attendant.
6.
There is no restriction check for LDN NIGHT CONNECTION destination stations. The station can be
totally restricted from receiving incoming calls and still receive LDN NIGHT CONNECTION calls.
7.
If the Night transfer destination station is busy, LDN calls will go into queue.
8.
If the system is switched to Day mode while LDN calls are in queue, only those calls that are in queue will
be redirected to the Attendant. LDN calls that are ringing the Night transfer destination station will
continue to ring that station and will not be redirected to the Attendant.
9.
If the Night transfer destination station is in the Make Busy state (MBST Command = 1 for that station)
or is in LINE LOCKOUT [L-3], the LDN call will go to TRUNK ANSWER FROM ANY STATION [T-8].
10.
If the Night transfer destination station (station A) is in CALL FORWARDING-BUSY LINE [C-2] to
station B and both stations (station A and station B) are busy, the incoming LDN call will queue to both
station A and station B, and will ring the first idle station.
11.
If the Night transfer destination (station A) is in CALL FORWARDING-BUSY LINE [C-2] over CCIS
to station C in the remote office, and both station A and station C are busy, busy tone is returned to the
incoming LDN calling party.
12.
Incoming LDN calls to a Night transfer destination station that has set CALL FORWARDING-ALL
CALLS, BUSY LINE, DON’T ANSWER-CCIS [C-45, C-46, C-47] over CCIS to a busy UCD group in
the remote office will queue to that group, and will activate the CALL WAITING LAMP-UCD [C-76], if
programmed.
Programming
STEP 1:
ALDN
- Assign LDN number and its transfer destination.
TN:
Tenant Number
LDN:
Listed Directory Number (must match station numbering plan)
Night Transfer: Y/N
If no, then LDN will only go to Attendant.
If yes, then the following parameters will be enabled:
TYPE:
Night Transfer Type
1: Station number
2: Outside (up to 8 digits)
3: ADC (when more than 8 digits are required)
STN:
For Types 1 & 2.
For Type 1, assign station number here.
For Type 2, assign access code and outside number here.
(A CCIS remote office station number can be input here also).
ADC:
For Type 3.
Input ADC number desired as assigned in the ASPD command.
STEP 2:
ACFR
- Assign TSFI: 2 (Night Connection-Fixed) to be allowed CCI: 1 (LDN). This allows LDN to
go to night transfer destination. Assign TSFI: 5 (TAS) to be allowed CCI: 1 (LDN). This allows LDN
to go to TRUNK ANSWER FROM ANY STATION [T-8]. Restrict if not using TAS.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...