MF Signaling - DID
M-84
Service Conditions (cont’d)
4.
Connection patterns to which MF signaling system can be applied are as follows:
a.) Individual call origination by station
b.) Attendant-to-Attendant connection
c.) Individual call origination by Attendant
d.) Call origination by Attendant via station/trunk
e.) MF line connection from CONSULTATION HOLD [C-17]
f.) Call transfer to MF line via Call Forwarding.
5.
Connection to the following services is not available:
a.) Call origination services to MF lines, such as, OUTGOING TRUNK QUEUING
b.) Call termination services from MF lines, such as, UCD [U-1]
c.) Call Waiting, REMOTE ACCESS TO SYSTEM [R-2].
6.
Assignment of MF signaling system or DP, PB signaling system can be determined on a per route basis.
7.
A PA-8RSTK (8RST) circuit card is required for performing this service.
Programming
STEP 1:
ASYD
- System 1, Index 234, Bit 0.
(0) No reverse-type connection acknowledgment
STEP 2:
ANPD
- Assign the first digit of the MF line access code.
STEP 3:
ASPA
- Assign the LCR or LCR (S) access code by providing a dummy route.
STEP 4:
AMND
- Assign the maximum number of necessary digits to the Dial (Area/Office) Code.
STEP 5:
ARNP
- Assign the access code to the route number. When multiple access codes are present by
alternative routing, set one of them.
STEP 6:
ARTD
- MF line- Assign the following data, depending on the trunk type, as shown below:
Dummy route-Assign 1 at all times for CDN 13:AC. The route data of the dummy route is TCL = 1,
AC = 1 and L/T = 1.
For the others, assign 0 in all cases.
Assign the following route class data to the route of the MF line.
TCMN = 0, TCMC = 0, MFSP: MF Sending Speed.
KPST: Duration of KP sending,
KPPT: Pause after KP sending,
CNI:
CNI Calling Number Identification format (=1)
Assign CDN 22:CNI = 1.
STEP 7:
ATRK
- MF line-Assign the LENS data of each trunk.
MF Register/Sender-Assign the following data to the LENS of the PA-8RSTK circuit card.
RT = 904: MF Register
RT = 905: Sender
TRUNK
TYPE
OSGS
ONSG
ISGS
INSG
LSG
DISPLAY
OGT
7
4
0
0
5
1
ICT
0
0
7
4
5
1
BWT
7
4
7
4
5
1
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...