background image

Web Connect Device 

For use with the following Systems: 
AquaLink

®

 RS Systems: Rev R Firmware or later

AquaLink PDA Systems: Rev 6.0 Firmware or later
AquaLink Z4 Systems: All Firmware versions

iAquaLink

 

2.0

H0435500 Rev B

INSTALLATION MANUAL

 WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in 

pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. 

The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so 

that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all 

warning notices and instructions that accompany this product. Failure to follow warning notices and instructions 

may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property 

damage, or death. 

 ATTENTION

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 

device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in 

a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio communications.  However, 

there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.
•  Consult the dealer or an experienced radio/TV technician for help.
Modifications made to this equipment, which are not authorized by the manufacturer, may void the user’s authority 

to operate this equipment.

Содержание iAquaLink 2.0

Страница 1: ...onditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has bee...

Страница 2: ......

Страница 3: ...AquaLink 2 0 Device on the web 10 4 6 LED Status Indicator Lights 10 4 7 Account and Location Setup 11 4 8 iAquaLink Apps and Web Interface 11 Section 5 Web Interface Home Screen 11 5 1 Title Bar 12 5...

Страница 4: ...inutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should consult a physician before us...

Страница 5: ...vided if this device is used to control underwater lighting fixtures The conductors on the load side of the ground fault circuit interrupter shall not occupy conduit boxes or enclosures containing oth...

Страница 6: ...ep is for the AquaLink RS with revision N firmware or newer ONLY For AquaLink PDA systems please go to section 3 2 WARNING Potentially high voltages in the power center can create dangerous electrical...

Страница 7: ...3 Unplug the power center transformer 24 VAC power plug from the 24 VAC 3 pin terminal on the power center PCB and bezel assembly as shown in Figure 2 4 Disconnect all terminal bars and input output c...

Страница 8: ...ket of the cable approximately 6 15 cm 6 Strip each wire 6 mm and connect to the red wire connector on the power center PCB A multiplex kit P N 6584 may be required if there are more than two 2 cables...

Страница 9: ...clear the Wi Fi settings and put the iAquaLink in desired setup mode 3 After clearing the WiFi settings and with the Wired WiFi switch set to WiFi use a smartphone or WiFi enabled device and go to Wi...

Страница 10: ...ce Wrap the cable inside the J box and route it through the break away hole 4 Using an Ethernet RJ45 cable connect the iAquaLink 2 0 device to the homeowner s router 5 Reinstall the cover and gasket o...

Страница 11: ...S systems only Using any computer or mobile device the iAquaLink web interface may be used to program configure control every device and feature available in the AquaLink RS system How to Access the W...

Страница 12: ...e current date time The title of the current menu in use will always be shown on the title bar This portion of the screen does not respond to commands 5 2 Middle Info Panel The middle info panel on th...

Страница 13: ...PM Set Date Time Time 00 00 PM Click ENTER when finished 6 3 Scheduling and Adding Devices CAUTION Make sure DATE and TIME are set up correctly before programming and scheduling any devices The SCHEDU...

Страница 14: ...Other Devices On Off Thu June 23 2011 3 03 PM MENU CUSTOMIZE HOME 1 Select label group 2 Select label name from list 3 Touch icon to assign General Aux OneTouch Page Page General Items Filter Pump VS...

Страница 15: ...board is revision 6 0 or later for PDA control system 3 If CPU board is installed correctly replace the power center PCB Some buttons do not operate from the iAquaLink 2 0 nor from the power center ov...

Страница 16: ...s 2013 Zodiac Pool Systems Inc H0435500 Rev B Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca Zodiac Pool Systems Inc 262...