The wireless iAquaLink 2.0 device will transmit
through walls and around corners. The transceivers do
not require line of sight to communicate. Steel framing,
aluminum siding, wrought iron, cyclone fences, leaded
glass, and other 2.4 GHz frequency items may inhibit/
prevent communication between the iAquaLink 2.0
J-Box and the WiFi Access Point.
4.1
Outdoor Installation
WARNING
Potentially high voltages in the power center can
create dangerous electrical hazards, possibly
causing death, serious injury or property damage.
Turn off power at the main circuit feeding the power
center to disconnect the power center from the
system.
Never run high voltage and low voltage in the same
conduit.
1. Turn off all power to the power center.
2. Mount the outdoor iAquaLink 2.0 J-box at least six
(6) feet (1,8 m) above the ground, at least ten (10)
feet (3 m) from any motor or air blowers that may
be in the vicinity, and at least five (5) feet (1.5 m)
away from other transceiver J-boxes. See Figure 3.
NOTE
To improve performance of the transceiver,
mount the iAquaLink 2.0 device more than six
(6) feet (1.8 m) above the ground.
3. Open the door to the power center and remove the
dead panel.
4. Pull cable through a knockout and into the low
voltage area.
5. Strip back the insulation jacket of the cable
approximately 6" (15 cm).
6. Strip each wire ¼" (6 mm) and connect to the
red, wire connector on the power center PCB. A
multiplex kit (P/N 6584) may be required if there
are more than two (2) cables running to a red, wire
connector on the PCB.
4.2
Indoor Installation
WARNING
Potentially high voltages in the power center can
create dangerous electrical hazards, possibly
causing death, serious injury or property damage.
Turn off power at the main circuit feeding the power
center to disconnect the power center from the
system.
iAquaLink 2.0
Device
Minimum
10’ (3 m)
Pump, Motor or
Air Blower
6’
(1,8 m)
Ground Level
Router
Computer
Internet Service
Provider
Wireless
or
Wired Connection
Low
Voltage
Area
Red 4-Pin
Terminal Bar
Internet
NOTE
When installing the iAquaLink 2.0 device
indoors, if another AquaLink wired interface
(ie. OneTouch
™
, All-button, etc.) is mounted
indoors, the two devices may share an RS-485
(4-wire) cable to communicate from inside the
home to the AquaLink control panel. In this
scenario, the RS-485 cable from the iAquaLink
2.0 device should be connected to the red
4-wire connector in the back of the wired
interface. The red 4-wire connector will then
have two cables running to it: the cable from the
iAquaLink 2.0 device, and the cable that runs to
the AquaLink system on the equipment pad.
Figure 3.
iAquaLink 2.0 J-Box Outdoor Installation
Page 8
iAquaLink™
2.0
Web Connect Device for AquaLink
®
Control Systems
|
Installation Manual