Toshiba VP Systems Release 7.1
July, 1994
5-70
Installation and Maintenance Manual
Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
Source
Remedy
Priority
36: System RAM
Error
Cache module found
an error with system
RAM, CPU and/or
VCU
Call Toshiba Technical Support for
remedy.
3
01 =
02 =
03 =
04 =
05 =
06 =
07 =
08 =
09 =
10 =
11 =
DATA-1 : ERROR CODE:
FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE
CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA = 1 OR 2
RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG (slot = CPU)
RAM SIZE GREATER THAN STANDARD SIZE OF 5 MEG
(obsolete Release 5.4 and later)
DATA-2: (D) = FIRMWARE REPORT OF MEGABYTES WHEN
DATA-1 = 3 OR 4
VCU CONTROL RAM > STD SIZE OF 2 MEG
(obsolete Release 5.4 and later)
VCU VOICE RAM > STD SIZE OF 4 MEG
(obsolete Release 5.4 and later)
VCU CONTROL RAM < STD SIZE OF 2 MEG (slot = VCU)
(obsolete Release 5.4 and later)
VCU VOICE RAM < Required amount for port count
(slot = first line card slot that goes beyond limit for existing RAM)
DATA2 = #MB needed for current port configuration
(if = FF, # ports configured > max expected)
DATA3 = # MB reported by VCU
DATA4 = # ports configured
VCU CONTROL RAM INSUFFICIENT FOR LANGUAGES LOADED
DATA 2 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 3 = N/A
DATA 4 = N/A
VCU RAM INSUFFICIENT FOR # FAX PORTS CONFIGURED
DATA 2 = # FAX PORTS SUPPORTED BY VCU RAM
DATA 3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 4 = VCU VOICE RAM SIZE IN MEGABYTES
VCU RAM INSUFFICIENT FOR # PORTS CONFIGURED
DATA 2 = # PORTS SUPPORTED BY VCU RAM
DATA 3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 4 = VCU VOICE RAM SIZE IN MEGABYTES
37: Ring Detection
Failure
TEST Line 4
Ensure that the PBX is properly
connected to the LIC, and check whether
the PBX type provides sufficient loop
current for the test. If the PBX is
properly connected and the PBX
provides sufficient loop current but the
test still fails, replace the LIC. If the PBX
type does not provide sufficient
loop current, to not use TEST Line 4.
2
DATA-1= UNEXPECTED EVENT TYPE
DATA-2= NOT USED
DATA-3= NOT USED
DATA-4= NOT USED
The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data associated with
the error.
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...