Toshiba VP Systems Release 7.1
July, 1994
MAINTENANCE
5-73
Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
Source
Remedy
Priority
44: CPU/VCU
Request/Reply
Checksum Error
A protocol error
occurred between the
CPU and VCU on the
control bus.
Contact Toshiba Technical Support.
3
DATA-1 =
DATA-2,
DATA-3,
DATA-4 =
NUMBER OF RETRIES ATTEMPTED BEFORE TRANSACTION
SUCCEEDED OR ABANDONED (MAXIMUM OF 3).
FAILURE REASON FOR EACH ATTEMPT:
01 =
02 =
03 =
04 =
05 =
06 =
NO ERROR (RETRY SUCCEEDED)
CONTROL BUS TIMEOUT ATTEMPTING TO READ
CPU CB STATUS REGISTER
CONTROL BUS TIMEOUT ATTEMPTING TO READ
VCU SHARED RAM
CONTROL BUS TIMEOUT ATTEMPTING TO WRITE
VCU SHARED RAM
INCORRECT CHECKSUM ON VCU REPLY BUFFER
VCU DETECTED CHECKSUM ERROR ON CPU
REQUEST BUFFER
45: VCU Reply
Language Set
Error
The VCU has replied
that there is an error
in a language set.
Contact Toshiba Technical Support.
3
DATA-1
DATA-2 — BIT MAP HI BITS
DATA-3 — BIT MAP HI BITS
= THIS ERROR NUMBER
= LOAD FAULT
= NOT LOADED
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...