Message Waiting (Response to Command the VP 300 Sent to SMDI)
Another type of call record received is for an error on a message waiting command to the SMDI. It
means that the station number indicated is not a valid Centrex MWI number and has not been
programmed as such.
The following is an example of an error record:
MWI2948395 INV
MWI is message waiting. 2948395 is the station for which message waiting stutter dial tone was to be
activated. INV indicates the station is invalid.
■
If a Call Record Is Not Received
If after “n” rings, as defined in System Parameter 99, 100 and 117, the call record has still not
been received, the caller hears the company greeting instead of the called party's station/name or
greeting. If this occurs, check whether:
•
The data link is out of operation — check all connections. Once connections are verified, test
to see if information can successfully be sent to or received over the link using a serial
terminal.
•
The phone system has a hardware problem.
•
The call is not programmed within SMDI to send call information to the VP 300 multi-line
hunt group.
The maintenance command MON2 allows incoming SMDI records to be monitored over
the RS-232C link.
Toshiba VP Systems Release 6.1 February, 1993
9-16
Installation and Maintenance Manual
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...