Quick Reference Guide
Hardware
Toshiba VP 300 System Specifications
Electrical Requirements
120 VAC System
Voltage Range
90–132 VAC
Frequency
47–63 Hz
Maximum Power
1,000 Watts
240 VAC System
Voltage Range
180–260 VAC
Frequency
47–63 Hz
Maximum Power
1,000 Watts
-48 VDC System
Voltage Range
42–60 VDC
Maximum Power
1,000 Watts
Remote Alarm
Alarm Relay
Closures
2 (major, minor)
Rating
0.5A at 48 VDC
Access
Rear, DB9 connector
Alarm Callout
Automatic Callout to configurable service number
Alarm Types
Major Alarm
Minor Alarm
Temperature Alarm
Alarm Temperature
< 50F or > 122F
(< 10C or > 50C)
Environmental Requirements
Temperature
Operating (Sea Level)
50F (10C) to 104F (40C)
Non-operating
-50F (-10C) to 129F (54C)
Gradient, operating
50F (10C) per hour, maximum
Gradient, non-operating
68F (20C) per hour, maximum
Humidity
Operating
20–80%, non-condensing
Atmosphere
Particulate Matter (max)
80 micrograms per cubic millimeter
Corrosive Gasses
< 10 ppm
Altitude
Operating:
-200 feet to 10,000 feet
(-61 meters to 3,048 meters)
Non-operating, transit:
-200 feet to 40,000 feet
(-61 meters to 12,192 meters)
Non-operating, storage:
-200 feet to 10,000 feet
(-61 meters to 3,048 meters)
Toshiba VP Systems Release 7.1 July, 1994
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...