Quick Reference Guide
Hardware
Toshiba VP 300 System Specifications
Routine Maintenance
Air Filter Cleaning
At least yearly
Fan Inspection
At least yearly
System Protection
Over-temperature
Shutdown
Disk Drive Spin
< 41F or > 131F (< 5C or > 55C) (automatic recovery)
Down
Power Supply
158F (70C) (circuit breaker trip, manual recovery)
Shutdown
Power Supply Unit Protection
Circuit Breaker
System overcurrent trip, manual recovery
Over Current
All 6 DC outputs, auto recovery
Over Voltage
All 6 DC outputs, circuit breaker trip, manual recovery
Over Temperature
Circuit breaker trip, manual recovery
Electrostatic Discharge
25 kV to chassis without disruption of operation
(ESD)
Power Line Disturbance
IEEE 587,1.5 kV maximum without disruption of operation
Telephony Port Isolation
3,750 VAC any port to ground
System Adjustments
Cabinet Adjustments
Levelers
Internal Adjustments
None
Time of Day Clock
Accuracy
Plus or minus 1 min/mo (at 77F/25C)
Battery Hold Time
> 1 year (at 77F/25C)
Battery Life
10 years (at 77F/25C)
Toshiba VP Systems Release 7.1 July, 1994
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...