Table 5-2 Boot ROM Diagnostic Errors (continued)
CPU
Error
No.
Description
Most Likely
Cause
00FH
010H
011H
012H
013H
015H
016H
017H
Fatal
Fatal
Z180 ASCI test error
Modem loopback test error
TOD RAM pattern or addressing test error
TOD alarm interrupt error
TOD not counting
Floppy disk controller test error
OCC write error
OCC read error
CPU
CPU
CPU
CPU
CPU
CPU
PSU
PSU
018H
019H
01AH
01BH
01CH
01DH
01EH
01FH
022H
023H
024H
025H
026H
027H
02BH
02CH
02DH
032H
033H
Erroneous write protect error during DRAM tests
Parity error not detected
Write protect not detected
Data corrupted during write protect test
Z180 CSIO test error
Analog to digital converter test error
+5V VCC out of range (+4.75 to +5.25V)
+5V clean out of range (+4.50V to +5.50V)
+12V clean out of range (+10.8V to +13.2V)
+12V motor out of range (+11.4V to +12.6V)
Battery out of range (+3.57V to +5.25V)
Temp out of range (<10 C or >50 C/<50 F or >122 F)
Z180 PRT test error
Unexpected NMI error
Unexpected interrupt error
Z180 DMAC test error
OCC checksum error
8254 timer error
Watchdog timer error
PSU
PSU
CPU
SYSTEM
CPU
CPU
CPU
CPU
CPU
CPU
CPU
CPU
CPU
CPU
OCC
OCC
OCC
CPU
CPU
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...