AC to DC Power Supply Conversion
Before proceeding, read the instructions in the section entitled Installing the VP 300 with a –48 VDC
Power Supply Unit, in the INSTALLATION chapter of this manual. Make sure that the material is
available to connect the cabinet to the –48 VDC power source.
The VP 300 may be powered by an AC or DC power source. The cabinet contains either an AC or DC
version of the power supply unit and power filter assembly to work with the power source selected. To
convert the VP 300 from an AC to a DC powered system, use the following instructions.
This conversion requires installation of the following subassemblies:
•
DC Power Supply Unit (Part No. 740-6027-001).
•
DC Filter Assembly (Part No. 740-6075-001).
•
DC Backplane Harness (Part No. 530-6021-001).
These subassemblies must be on hand before continuing.
◆
WARNING
◆
Damage to the VP 300 may occur if replacement procedures are not performed in the
order given.
Removing AC
To remove the AC subassemblies, follow the steps below.
Subassemblies
1.
Remove the AC Power Supply Unit (PSU) following the instructions
Removing Power Supply in this section.
2.
Remove the VCU and CPU PCAs from slots A13 and A14, respectively.
Toshiba VP Systems Release 7.1
July, 1994
5-106
Installation and Maintenance Manual
Conduit with three
10–gauge wires
DC
Power
Source
Earth Ground
Terminal Block and Ground
Stud on Back of VP 300
Figure 5-17 Field Wiring for –48 VDC Powered VP 300
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...