10.1.7
MITEL SX-200 DIGITAL MAINTENANCE
The following are the maintenance commands for the Mitel SX-200 Digital integration.
TEST INTEGRATION
This command tells the MIC to run its link selftest. The form of the
(TE INT x 1 or
command is:
TE I x 1)
TE INT x 1
where x is the slot number.
Any hardware errors found are logged in the Hardware Error Table. Refer
to the Installation and Maintenance manual — MAINTENANCE,
Hardware Errors.
(TE INT x 1 2)
This command resets the MIC board and takes approximately 30 seconds.
The form of the command is:
TE INT x 1 2
where x is the slot number, and 2 is the reset flag.
LIST INTEGRATION
This command lists the current state of the MIC board, the diagnostic
(L INT x 1)
status, the status of the links, and the pegs. The form of the command is:
L INT x 1
where x is the slot number.
An example listing is:
@L INT 4 1
********** INTEGRATION STATUS **********
CARD ID = Mitel
CARD STATUS = UP
DIAGNOSTIC = OK
LINK 1 STATUS = ACTIVE
LINK 2 STATUS = IDLE
LINK 3 STATUS = IDLE
LINK 4 STATUS = ACTIVE
PEGS:
MM/DD HH:MM
INDEPENDENT = 0 0 0 0 0
LINK 1 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 2 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 3 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 4 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Toshiba VP Systems
Release 7.1
July, 1994
MITEL SX-200 DIGITAL ADAPTIVE INTEGRATION
10.1-41
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...