Installation and Maintenance Manual
Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
Source
Remedy
Priority
33: Line Card
Hardware Error
Error logged by
selftest when start
LSP reply received
with either an error
status or an
unexpected OK
status (e.g., Slot is
empty or already
reported down)
Contact Toshiba Technical Support.
3
00 --
DATA-1 =
REPORTED STATUS
START LSP REPLY RECEIVED WITH EITHER AN ERROR STATUS
OR AN UNEXPECTED OK STATUS
00 --
01 --
02 --
03 --
04 --
05 --
06 --
DATA-2 =
REPORTED STATUS
LSP SUCCESSFULLY STARTED
SCSI ERROR WHILE LOADING LSP
DATA-4: VCU ERROR CODE
CARD TYPE IN SLOT DOES NOT MATCH CONFIGURED
TYPE
DATA-4: CARD TYPE ACTUALLY INSTALLED IN SLOT
CONTROL BUS ERROR - SLOT EMPTY OR CARD
NON-RESPONSIVE
FILE SYSTEM READ ERROR ACCESSING LSP IMAGE
CARD IN SLOT REPORTS FATAL DIAGNOSTIC ERROR
DATA-3: SUPPLEMENTAL CARD STATUS
BAD START LSP REQUEST
00 --
01 --
02 --
03 --
DATA-3 =
CURRENT SLOT STATE
EMPTY (UNCONFIGURED)
WAITING FOR INITIAL START LSP REPLY
RUNNING
ERROR
NO PORTS CONFIGURED FOR LINE CARD
LINE CARD DISALLOWED BY OCC
TOTAL PORTS > ALLOWED BY OCC
ERROR WRITING START LSP REQUEST TO VCU
DISK ERROR WHEN SEARCHING FOR LSP CODE A
01 --
02 --
03 --
04 --
05 --
The DATA-1 field specifies the type of error. DATA-2 and DATA-3 are data associated with
the error.
89 --
LIC REPORTED LIC IMAGE CHECKSUM ERROR
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...