Toshiba VP Systems Release 7.1
July, 1994
MAINTENANCE
5-71
Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
Source
Remedy
Priority
38: Disk Defect Boot
Region
Defect in secondary
bootstrap (Xboot)
region.
Attempt to reload the software code
from the floppy diskette to the hard disk.
If error repeats, replace the hard disk
indicated in DATA-1. If error repeats
again, call Toshiba Technical Support.
3
01 =
02 =
03 =
04 =
05 =
06 =
81 =
82 =
83 =
84 =
85 =
86 =
DATA-1 : DRIVE ID AND SEVERITY INDICATION
NON-FATAL ERROR, DRIVE 1
NON-FATAL ERROR, DRIVE 2
NON-FATAL ERROR, DRIVE 3
NON-FATAL ERROR, DRIVE 4
NON-FATAL ERROR, DRIVE 5
NON-FATAL ERROR, DRIVE 6
FATAL ERROR, DRIVE 1
FATAL ERROR, DRIVE 2
FATAL ERROR, DRIVE 3
FATAL ERROR, DRIVE 4
FATAL ERROR, DRIVE 5
FATAL ERROR, DRIVE 6
DATA-1 = LOGICAL DRIVE ID WITH DEFECTIVE XBOOT
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
39: Disk Defect File
System Region
Defect in file system
region of a system
disk.
Attempt to reload the software code
from the floppy diskette to the hard disk.
If error repeats, replace the hard disk
indicated in DATA-1. If error repeats
again, call Toshiba Technical Support.
3
DATA-1 = LOGICAL DRIVE ID WITH DEFECTIVE FILE SYSTEM
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
40: Non-Media Disk
Error
Non-media disk
error.
Call Toshiba Technical Support to have
information interpreted.
DATA-2 =
SCSI SENSE KEY
DATA-3 =
SCSI SENSE CODE
DATA-4 =
NOT USED
1
3
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...