The VP 300 normally answers the call immediately within one ring
upon receiving a call record from the MIC. This system parameter
provides for a fail-safe mode of operation. If the VP 300 does not
receive call information from the digit display links, ports answer
calls in AX mode and the caller hears the company greeting.
System Parameter 131 — DEV: SPEAK “DIAL ZERO FOR
ASSISTANCE”
Modify the value of System Parameter 131 to be YES to change the
prompt for a caller transferred to assistance from, “Please hold for
assistance…” to “Dial zero for assistance…”
System Parameter 170 — INTEGRATION LAMP ON/OFF LINK
MUST MATCH
Modify the value of System Parameter 170 to be YES.
System Parameter 191 — HOUR TO REACTIVATE MSG WTG
INDICATORS
Modify System Parameter 191 to be the hour of the day when the VP
System will perform automatic reactivation of message waiting indicators.
Because the PBX automatically cancels message waiting for Superset 4
display telephones after 24 hours, System Parameter 191 is required.
System Parameter 191 reactivates the message waiting indicator every 24
hours.
TRUNK GROUP
The TRUNK GROUP Table specifies call processing parameters for
Table
different trunk groups by VP 300 COS.
Configure Trunk Group 0 with a greeting for use with internal forwarded
calls received without extension numbers. The greeting should specify
that the person called does not have a mailbox on the system.
☞
For all software release levels lower than Generic 1003, Called
Party Identification identifies incoming trunks by their individual
trunk numbers, not by PBX trunk group numbers. This requires that
each individual trunk have its own entry in the VP 300 TRUNK
GROUP Table.
With Generic 1003, trunks may be identified by trunk group,
provided that the trunk group is assigned a name that follows the
Naming Conventions at the beginning of the Mitel SX-200 Digital
Configuration section of this chapter. A trunk that is not part of a
trunk group is identified by individual trunk number. All trunk
groups will also be identified by individual trunk number if Generic
1003, release E96.7 or later is used because of the COS option,
COV Voice Mail Port.
The VP 300 identifies calls from the attendant as coming from Trunk
Group 00, since a call from the attendant cannot be identified by
extension number. Refer to Direct Internal Calls in this section.
Refer to the Configuration manual — TRUNK GROUP Table.
Toshiba VP Systems
Release 7.1
July, 1994
MITEL SX-200 DIGITAL ADAPTIVE INTEGRATION
10.1-23
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...