Voltage control
5.1
PMBus commands to HW parameters
The voltage control module implements the PMBus reference voltage generation model from a high-level
perspective, as described in the PMBus Specification, Part II, Revision 1.3.1, section 9.2 and shown in
PMBus commands are converted to module input parameters by FW, as shown in
. Details of the
command to parameter computations for individual parameters can be found in
Figure 38
PMBus target voltage generation
Figure 39
Mapping of PMBus commands to voltage control parameter inputs
5.2
Ramp generator
The ramp generator is responsible for slewing the target output voltage during soft-start and shutdown, as well
as in response to commanded output voltage changes. For example:
•
During soft-start; from 0 V (or pre-bias voltage) to VOUT_COMMAND at the TON_RISE rate
•
During regulation; between two VOUT_COMMAND voltages at VOUT_TRANSITION_RATE
•
During shutdown; from VOUT_COMMAND to 0 V at the TOFF_FALL rate
VOUT_MARGIN_HIGH
VOUT_COMMAND
VOUT_MARGIN_LOW
OPERATION
+
+
-
VOUT_TRIM
Limiter
VOUT_MAX
VOUT_MIN
X
VOUT_SCALE_LOOP
X
vcontrol[14:0]
(Reference Voltage)
IOUT
See PMBus Part II
Revision 1.3.1 Figure 13
VOUT_CAL_OFFSET
VOUT_DROOP
VOUT_MARGIN_HIGH
VOUT_COMMAND
VOUT_MARGIN_LOW
OPERATION
X
VOUT_SCALE_LOOP
vc_vramp_target
VOUT_TRIM
VOUT_CAL_OFFSET
+
X
VOUT_SCALE_LOOP
vc_vcontrol_delta
VOUT_DROOP
MFR_RDROOP_RLL_NEG
MFR_RDROOP_RLL_SEG2
MFR_RDROOP_RLL_SEG3
X
VOUT_SCALE_LOOP
vc_vavp_rll
vc_vavp_rll_neg
vc_vavp_rll_seg2
vc_vavp_rll_seg3
VOUT_MAX
X
VOUT_SCALE_LOOP
vc_vcontrol_vout_max
VOUT_MIN
X
VOUT_SCALE_LOOP
vc_vcontrol_vout_min