XDPP1100 technical reference manual
Digital power controller
Fault handler
Peripheral Field name
Access Address
Bits
Description
faultcom
fault_block_on_shut
RW
7000_5404h [0]
Defines whether faults continued to
be reported after an initial
shutdown fault had occurred and
triggered shutdown.
0: Fault reporting continues after
shutdown fault.
1: Fault reporting blocked on new
faults after initial shutdown fault
occurs. Fault will continue to be
blocked until the shutdown fault is
cleared via fault_shut_clr_loop,
fault_shut_clr_com or
fault_shut_clr_all.
faultcom
fault_enable_com
RW
7000_5408h [31:0]
Fault enable for common faults.
Individual faults are enabled for
fault interrupt generation when
their corresponding bit is high. This
register is controlled by FW based
on the PMBus command
FW_CONFIG_FAULTS bits [167:136]
which have a 1 to 1 mapping with
bits [31:0] of this register.
0: Unused
1: Unused
2: IS1 (ISEN) tracking fault
3: IS2 (BISEN) tracking fault
4: Fbal1 fault 5: IS1 (ISEN) PCL fault
6: IS1 (ISEN) SCP fault
7: Fbal2 fault
8: IS2 (BISEN) PCL fault
9: IS2 (BISEN) SCP fault
10: Unused
11: VREF open fault
12: VSEN open fault
13: Unused
14: VRREF open fault
15: VRSEN open fault
16: Unused
17: BVREF_BVRREF open fault
18: BVSEN_BVRSEN open fault
19 to 31: Unused
faultcom
fault_shut_clr_all
W
7000_540Ch [0]
Clears shutdown faults in
fault_reg_com and both
fault_reg_loop registers when high.
This field should not be written
until after FW has completed
shutdown-related cleanup (e.g.,
V
control
target returned to 0,
appropriate blocks disabled).