Compensator
Peripheral Field name
Access Address
Bits
Description
7000_201Ch
(pid1)
BVRSEN). Used only when selected
by pid_ff_vrect_sel. If computing
from V
IN
,
pid_ff_vrect_override(U12.0) =
V
IN
(V) * 800 *
MFR_VRECT_SCALE(U0.12) *
MFR_TRANSFORMER_SCALE(U0.12)
/ (2^12 * 2^12)
LSB = 1.25 mV, range = 0.0 to
5.11875 V
pid
pid_ff_override
RW
7000_1C20h
(pid0)
7000_2020h
(pid1)
[9:0]
PID FF override value. Used when
selected by pid_ff_override_sel.
This parameter along with
pid_ff_override_sel may be used to
override the HW-computed FF with
a FW computation appropriate for
boost or buck-boost derived
topologies.
LSB = 2^-10, range = 0.0 to 0.9990
pid
pid_ff_override_sel
RW
7000_1C20h
(pid0)
7000_2020h
(pid1)
[10]
PID FF override select.
0: Use computed FF with V
RECT
selected by pid_ff_vrect_sel
1: Use pid_ff_override
pid
pid_ff_one_div_
vout_scale_loop
RW
7000_1C24h
(pid0)
7000_2024h
(pid1)
[8:0]
Conversion factor for computing
V
OUT
from the measured VSADC
output. This parameter is
computed automatically by the
default FW and requires no action
by the user.
Computed by FW from PMBus
commands as follows:
pid_ff_one_div_vout_scale_loop(U
6.3) = 2^19 /
VOUT_SCALE_LOOP(U0.16), clamp
to 2^9-1
LSB = 0.125, range = 0.0 to 63.875
pid
pid_ff_i82_div_trans_
scale_loop
RW
7000_1C24h
(pid0)
7000_2024h
(pid1)
[27:9]
Conversion factor for computing
1/V
RECT
from the TSADC V
IN
measurement. This parameter is
computed automatically by the
default FW and requires no action
by the user.
Computed by FW from PMBus
commands as follows:
exp =
$signed(MFR_TRANSFORMER_SCAL
E[15:11]), exp = -10, -11, -12
supported
quot1(U5.7) = 2^(-3-exp) /