User Manual
53 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Current sense (IS)
Figure 30
Simplified block diagram of the ISP
The ISP also includes several phase current-based fault checks, as shown in
. These fault checks
include:
•
Peak current limit (PCL)
•
Negative current limit
•
Short-circuit fault
•
Error tracking fault
The main functionalities of the ISP are described in the following subsections, including the relevant user-
definable parameters.
3.3.1
ADC codes to amps
The process to convert the ADC codes into amps requires three steps and is illustrated in
. The
relevant steps are as follows:
•
CE output synth_i (represented in ADC codes) is multiplied by the PMBus command MFR_IOUT_APC (APC
refers to
“a
mps per code
”
, converting the code-based word synth_i into a digital representation of amps).
•
The resulting APC multiplication output is then summed with the PMBus command IOUT_CAL_OFFSET to
adjust for offset errors.
•
The reconstructed waveform in amps is averaged over one switching cycle to produce a cycle average
current.
synth_i
MFR_IOUT_APC
S
+
+
IOUT_CAL_OFFSET
Cycle
average
sync_fsw
iout_cavg
(from CE)
pwm_state
Negative
current limit
isp_ncl_thresh
ncl_fault
Short circuit
fault
isp_scp_thresh
scp_fault
Peak
current limit
ce_current_limit
pcl_fault
Tracking
fault
is_track_fault
(To digital PWM)
(To telemetry)
(To fault block)
(To fault block)
(To digital PWM)
isp_track_fault_en
isp_err_ratio_sel
ierr
(from AFE quantizer)