![Infineon XDPP1100 Technical Reference Manual Download Page 199](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193199.webp)
User Manual
199 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Telemetry
Table 57
PRISEN ADC LPF BW programming, where LSB = 0.0001221 and F
sample
= 0.25 MHz. Applicable
to PRISEN when ts_muxmode = 6, 7 and IMON when ts_muxmode = 4, 6.
tlm_kfp_prisen K
FP
kfp_real
F3dB
(kHz)
tlm_kfp_prisen K
FP
kfp_real
F3dB
(kHz)
0
4
0.0005
0.019
20
128
0.0156
0.632
1
5
0.0006
0.024
21
160
0.0195
0.793
2
6
0.0007
0.029
22
192
0.0234
0.955
3
7
0.0009
0.034
23
224
0.0273
1.119
4
8
0.0010
0.039
24
256
0.0313
1.284
5
10
0.0012
0.049
25
320
0.0391
1.617
6
12
0.0015
0.058
26
384
0.0469
1.957
7
14
0.0017
0.068
27
448
0.0547
2.302
8
16
0.0020
0.078
28
512
0.0625
2.653
9
20
0.0024
0.097
29
640
0.0781
3.372
10
24
0.0029
0.117
30
768
0.0938
4.116
11
28
0.0034
0.136
31
896
0.1094
4.886
12
32
0.0039
0.156
32
1024
0.1250
5.684
13
40
0.0049
0.195
33
1280
0.1563
7.368
14
48
0.0059
0.235
34
1536
0.1875
9.182
15
56
0.0068
0.274
35
1792
0.2188
11.141
16
64
0.0078
0.313
36
2048
0.2500
13.263
17
80
0.0098
0.392
37
2560
0.3125
18.086
18
96
0.0117
0.472
38
3072
0.3750
23.873
19
112
0.0137
0.552
39
3584
0.4375
30.947
Table 58
PRISEN ADC LPF BW programming, where LSB = 0.0001221 and F
SAMPLE
= 0.5 MHz. Applicable to
PRISEN when ts_muxmode = 4, 5.
tlm_kfp_prisen
(ts_muxmode =
4, 5)
K
FP
kfp_real
F3dB
(kHz)
tlm_kfp_prisen
(ts_muxmode
= 4, 5)
K
FP
kfp_real
F3dB
(kHz)
0
4
0.0005
0.039
20
128
0.0156
1.263
1
5
0.0006
0.049
21
160
0.0195
1.585
2
6
0.0007
0.058
22
192
0.0234
1.910
3
7
0.0009
0.068
23
224
0.0273
2.237
4
8
0.0010
0.078
24
256
0.0313
2.567
5
10
0.0012
0.097
25
320
0.0391
3.235
6
12
0.0015
0.117
26
384
0.0469
3.914
7
14
0.0017
0.136
27
448
0.0547
4.604
8
16
0.0020
0.156
28
512
0.0625
5.305
9
20
0.0024
0.195
29
640
0.0781
6.744
10
24
0.0029
0.234
30
768
0.0938
8.232