2021-08-25
XDPP1100 technical reference manual
Digital power controller
Telemetry
Peripheral Field name
Access Address
Bits
Description
7: Loop 1 V
IN
8: Loop 0 duty
9: Loop 1 duty
10: Loop 0 F
switch
11: Loop 1 F
switch
12: ATSEN
13: BTSEN
14: Internal temp.
15: IMON
16: PRISEN
17: XADDR1
18: XADDR2
19 to 31: Unused
tlmcom
tlm_irq_gereric_thr_15
RW
7000_5040h [15:0]
Telemetry IRQ 15 threshold.
Compared against signal selected
by tlm_irq_thr_src_sel_15. Format
based on selected source.
I
OUT
: S9.4, LSB = 62.5 mA, range =
-256 to +255.9375 A
V
OUT
: U12.3, LSB = 156.25 µV, range =
0.0 to 5.11984375 V
I
IN
: U6.7, LSB = 7.8125 mA, range =
0.0 to 63.9922 A
V
IN
: U7.4, LSB = 62.5 mV, range = 0.0
to 127.9375 V
Duty: U0.16, LSB = 2^-16, range =
0.0 to 0.99998
F
switch
: U11.0, LSB = 1 kHz, range = 0
to 2047 kHz
ATSEN, BTSEN, ITSEN: U10.0, LSB =
1 ADC code, range = 0 to 1023 ADC
codes
IMON, PRISEN, XADDR1, XADDR2:
U10.4, LSB = 0.0625 ADC code,
range = 0.0 to 1023.9375 ADC codes
tlmcom
tlm_irq_thr_src_sel_15
RW
7000_5040h [20:16] Telemetry IRQ 15 source select.
Selects signal to compare against
tlm_irq_gereric_thr_15 for IRQ
generation.
0: Loop 0 I
OUT
1: Loop 1 I
OUT
2: Loop 0 V
OUT
3: Loop 1 V
OUT
4: Loop 0 I
IN
5: Loop 1 I
IN
6: Loop 0 V
IN
7: Loop 1 V
IN
8: Loop 0 duty
9: Loop 1 duty
10: Loop 0 F
switch