![Infineon XDPP1100 Technical Reference Manual Download Page 289](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193289.webp)
User Manual
289 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Current sharing (ISHARE)
10.4
Current sharing pin, DAC and ADC configuration
Some additional parameters are required to be set for the proper active current sharing operation.
shows relevant register programming in order to configure the IMON pin for current sharing. Correspondingly,
shows the register settings in order to configure the DAC and TSADC for current sharing.
Table 68
IMON pin current sharing parameter configuration
Register
Current sharing setting
Notes
imon_func
0
Connects IMON pin to the DAC and
TSADC
imon_pd
0
Disables weak pull-down resistor
on IMON pin
imon_pu_n
1
Disables weak pull-up resistor on
IMON pin
imon_ppen
0
Sets digital output drive to open
drain
Table 69
Current DAC and TSADC current sharing parameter configuration
Register
Current sharing setting
Notes
imon_meas_en
1
Allows IMON input to be measured
by TSADC
ts_tsidac_imon_sel
1
Connects current DAC output to
IMON pin
ts_muxmode
4, 6 or 7
These settings include
measurement of the IMON input in
the TSADC input mux auto
sequencing
10.5
R
ishare
FW patch
The average current value at the IMON pin depends on the configuration and sequencing of the parallel
connected power supply modules. Therefore, the R
ishare
resistor needs to be connected differently depending on
the module configuration. The following resistor connections are to be applied:
•
If parallel modules are all enabled simultaneously from start-up, R
ishare
is connected between IMON pin and
ground (
and
).
•
If parallel modules start in a sequence or are disabled for power reduction, R
ishare
is connected between:
o
IMON pin and PWM6 for XDPP1100-Q024 (
o
IMON pin and PWM6 or PWM11 for XDPP1100-Q040 (
For the second R
ishare
connection with module sequencing, a FW patch is available. It drives the R
ishare
negative
connection to ground through a PWM output allowing the negative connection to float when the supply is not
enabled. The PWM pin selection is hard-coded in the FW patch.