XDPP1100 technical reference manual
Digital power controller
Fault handler
Command name
Access Length Address Bits
Description
corresponding fault.
0: Unused
1: Unused
2: IS1 (ISEN) tracking fault
3: IS2 (BISEN) tracking fault
4: Fbal1 fault
5: IS1 (ISEN) PCL fault
6: IS1 (ISEN) SCP fault
7: Fbal2 fault
8: IS2 (BISEN) PCL fault
9: IS2 (BISEN) SCP fault
10: unused
11: VREF open fault
12: VSEN open fault
13: Unused
14: VRREF open fault
15: VRSEN open fault
16: Unused
17: BVREF_BVRREF open fault
18: BVSEN_BVRSEN open fault
19 to 31: Unused
[199:168]
Fault_t2_shut_mask_loop_hw[31:0]
:
Masking for loop hw fault shutdown on
pwm ramp t2 time (usually falling edge
of PWM pulse). Bits [199:168] correspond
to bits [31:0] of HW parameter
fault_t2_shut_mask_loop. Set
corresponding bit high to enable fault
shutdown on t2. Note that the fault must
still be enabled for shutdown via the
corresponding PMBus
“
RESPONSE
”
command.
0: Reserved
1: VOUT_OV_FAULT
2: VOUT_OV_WARN
3: VOUT_UV_FAULT
4: VOUT_UV_WARN
5: VIN_OV_FAULT
6: VIN_OV_WARN
7: VIN_UV_FAULT
8: VIN_UV_WARN
9: IOUT_OC_FAULT
10: IOUT_OC_LV_FAULT
11: IOUT_OC_WARN
12: IOUT_UC_FAULT
13: MFR_IOUT_OC_FAST
14: IIN_OC_FAULT
15: IIN_OC_WARN
16: OT_FAULT
17: OT_WARN