Telemetry
Figure 72
Switching frequency telemetry block diagram
8.10
General-purpose ADC telemetry
The general-purpose TSADC outputs are low-pass filtered as illustrated in the block diagram in
. The
IMON and XADDR BWs are programmed via registers
tlm_kfp_imon
and
tlm_kfp_xaddr
according to the
following definition:
•
tlm_kfp_xaddr
follows the BW programming given in
•
For
ts_muxmode
= 5, 7;
tlm_kfp_imon
follows the BW programming given in
•
For
ts_muxmode
= 4, 6;
tlm_kfp_imon
follows the BW programming given in
The
tlm_kfp_imon
BW programming depends on the
ts_muxmode
selection due to the different sample rates.
Figure 73
General-purpose ADC telemetry block diagram
The PRISEN BW is programmed through register
tlm_kfp_prisen
and follows a slightly different BW
programming table, since it is sampled twice in the TSADC sampling cycle. The PRISEN BW programming is
defined in
ts_muxmode
= 5, 7 and in
ts_muxmode
= 4, 5.
sync_tswitchX[10:0]
U11.0
F = 1/T
25MHz
tlmX_freq[10:0]
U11.0
RO parameters
D
Q
Q
SET
CLR
tlm_kfp_prisen[5:0]
ts_prisen_adc[13:0]
U10.4
LPF
25 MHz
tlm_prisen_lpf[13:0]
U10.4
ts_prisen_adc_update
ts_imon_adc[13:0]
U10.4
LPF
25 MHz
tlm_imon_lpf[13:0]
U10.4
ts_imon_adc_update
ts_xaddr1_adc[13:0]
U10.4
LPF
25 MHz
tlm_xaddr1_lpf[13:0]
U10.4
ts_xaddr1_adc_update
tlm_kfp_imon[5:0]
tlm_kfp_xaddr[5:0]
ts_xaddr2_adc[13:0]
U10.4
LPF
25 MHz
tlm_xaddr2_lpf[13:0]
U10.4
ts_xaddr2_adc_update
RW parameters
RO parameters