Maintenance Commands
555-233-143
7-182
Issue 1 May 2002
Output
The following example shows the output from the
list measurements ethernet
command.
Field Descriptions
Date
The date that the data was collected.
Time
The current 15-minute interval in which the action was performed
CRC Check
The error count for CRC errors
Total
The total value of the counter on the board
NOTE:
The counter value can be up to 11 digits long because of the 32-bit
counter on the board. After the occurrence of an “N/A,” the delta
equals the total. Busying out or releasing a board or a port, using the
reset board command, and reseating the board all clear the firmware
counters.
Delta
The difference between the current and the previous sample
Collision
Count
The error count for collisions on the ethernet
list measurements clan ethernet 1C1017 Page 1 of x
Switch Name: sierra
Date:4:07pm MON AUG 01,1999
C-LAN ETHERNET PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Collision Count
total delta total delta
08/01 0308 650 50 650 250
08/01
0253
600 600 400 400
08/01
0238
N/A N/A N/A N/A
08/01
0223
1000000570 20 10000000570 20
08/01
0208
1000000550 10000000550 10000000550 10000000550
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...