PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1229
555-233-143
1116
ABORT
The port is in an out-of-service ISDN service state.
1. A call cannot be present if the port is in an ISDN out-of-service state, so a
call state audit would be inappropriate. No action necessary. (Use the
status pri-endpoint extension command to investigate the ISDN state of
the port).
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
1. Reconnect the disconnected PRI terminal adapter or disable the rollabout
video feature on this circuit pack. To do the latter, enter change ds1
UUCSS and set the
Alarm when PRI Endpoint Detached?
field
to y.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This switch sent a call-state auditing message to the far-end terminal adapter
to verify the state of the call active on this port. If a call-state mismatch is
found, then the call is torn down within two minutes. If no call was active, then
no message was sent.
Table 8-503.
Test #257 Call State Audit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...