Maintenance-Object Repair Procedures
555-233-143
8-780
Issue 1 May 2002
5. Replace faulty components and reconnect the original fiber. Be sure to
reconnect the fibers properly as noted in step 3. If there is a problem with
the port network after re-connecting the fiber, and the port network is
connected to a Center Stage Switch, run the Configuration Audit via the
test board command on the SNI circuit pack to which the intervening fiber
is connected. See the SNI-BD section for instructions on interpreting
results.
6. Release EI circuit pack or SNI circuit pack with the release board UUCSS
command.
Figure 8-39.
Interconnection of Lightwave Transceiver Transmit/Receive Jacks
Tx
Rx
Transceiver
Lightwave
Back Skin of Cabinet