TIE-TRK (Analog Tie Trunk)
Issue 1 May 2002
8-1647
555-233-143
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx command to determine the trunk group/member
number of the port. Use the status trunk command to determine the service
state of the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. You must wait until the port is idle before
retesting.
1018
ABORT
The test has been disabled via administration.
Verify that the 'Maintenance Test' field on the 'Trunk Group' form is set to 'n.’
To enable the test, issue the 'change trunk-group x' command (x equals the
number of the trunk group to be tested). Then, change the entry in the
'Maintenance Test' field on the form to 'y.'
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
7,
FAIL
The conference capabilities of the port failed (Error Code 7).
129,
The reflective 404-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 129).
131, or
The reflective 1004-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 131).
133
The reflective 2804-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems are
suspected (see notes on the next page).
1. To make sure the problem is on-board, disconnect the port from the CO
and retry the test. Coordinate this with the CO, or do it after busy hours;
otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the test. If
the retry passes and troubles have been reported, refer the problem to the
CO.
More information continues on the next page.
Table 8-640.
Test #33 Looparound and Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...