Maintenance-Object Repair Procedures
555-233-143
8-48
Issue 1 May 2002
Call the terminal equipment and verify that the terminal rings. If the
terminal does not ring, then replace it. Otherwise, issue the test port
UUCSSpp command, and follow the procedure for Test #48.
Aux Data 40977 indicates that no terminal equipment was connected when
ringing was attempted. Run the short test via the test port UUCSSpp
command, and follow the procedure for the results of Test #48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reseat or replace
the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog circuit pack in the
system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, then it is probably a problem with the ringing
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the customer or the terminal equipment,
disable it by setting the
Tests
field on the change station extension form
to
n
. On some software releases, this will also disable Tests #6, 7, 161,
and 35.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Battery Feed test (#35), you may also clear errors generated from other tests in
the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Battery Feed test (#35)
X
X
ND
Station Present test (#48)
X
X
ND
Looparound test (#161)
X
ND
Conference test (#7)
X
ND
NPE Crosstalk test (#6)
X
ND
Station Status and Translation Audits and Updates test
(#36)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...