Maintenance-Object Repair Procedures
555-233-143
8-1138
Issue 1 May 2002
Modem Pool NPE Crosstalk Test (#96)
This test is destructive.
The Modem Pool Crosstalk test verifies that the NPE is connected only to the
desired time slot and is not crosstalking on other time slots. This test operates
exactly like Test #6 for other types of port circuits but is performed twice in order to
test both NPEs in the Modem Pool Port.
Table 8-467.
Test #96 Modem Pool NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required for this test are not available. The port may be in
use on a valid call. Determine whether the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Determine whether the port
is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABORT
The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack, and attempt to diagnose the previously existing errors.
2000
ABORT
A response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...