Maintenance Commands
555-233-143
7-192
Issue 1 May 2002
The following field descriptions pertain to the detailed reports accessed by the
list
measurements ds1-log and list measurements ds1-facility log commands.
Counted
Since:
The start time and date when the associated measurement counters were cleared
or the DS1C circuit pack was administered.
Date
The date of the 15-minute interval.
Time
The time of the 15-minute interval.
Errored
seconds
The value of the errored seconds counter for the specified 15-minute interval.
This field has a value from 0 to 900 or N/A if the data for the 15-minute interval is
invalid.
Bursty err
secs
The value of the bursty errored seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for the 15-minute
interval is invalid.
Valid
interval
This field indicates whether the data for the specified 15-minute interval is valid.
Data is considered valid when a count for that 15-minute interval. If the field has a
value of y, the data for the four error categories is valid; otherwise, the data is
invalid. Data is considered valid when a count for that 15-minute interval is
retrieved and none of the following invalid conditions occur. Data is invalid if a
system warm start or a system cold start occurred during the interval, if the DS1C
circuit pack was not inserted during the interval, if the system time was changed
during the interval, or if the system was too busy to respond to a poll request for
the interval.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...