set synchronization
Issue 1 May 2002
7-285
555-233-143
set synchronization
This command sets a specific DS1 trunk, Tone-Clock circuit, or ATM switch as the
reference source for system synchronization signals. It is permitted only after
synchronization has been disabled with disable synch. Any administered DS1
trunk or active Tone-Clock may be entered with the set command. The DS1 or
Tone-Clock will remain the synchronization reference until either the set command
specifies another circuit pack, or enable synchronization is entered.
After an enable synchronization, the administered primary or secondary
synchronization source will become the synchronization reference. If no primary
or secondary source is administered, the active Tone-Clock is used as the
synchronization reference.
This command is not supported when ATM-PNC is enabled.
Output
Table 7-44.
set synchronization command parameters
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
set synchronization
init
inads
craft
none
none
set synchronization 8a01
Command successfully completed
Command:
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...