VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 May 2002
8-1819
555-233-143
Notes:
a. Error Type 1 — Circuit pack stopped functioning or is not physically
present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (reset board
UUCSS).
3. If the error persists, replace the circuit pack.
b. Error Type 18 — The VAL circuit pack is busied out.
c. Error Type 217 — Applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257 — Transient communication problem between switch and
circuit pack; does not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop test indicate circuit pack
hardware failure.
3845 (v)
Any
3846 (w)
Any
3848 (x)
Any
3851 (y)
Any
3852 (z)
Any
3853 (aa)
Any
3854 (ab)
Any
3855 (ac)
Any
3856 (ad)
Any
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...