Table 8-359.
DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test board UUCSS
1(a)
0
Circuit pack removed or
SAKI test (#53)
MIN/WRN
OFF
18(b)
0
busyout board UUCSS
WARNING
OFF
release board UUCSS
23(c)
0
Board administered but not
inserted
WARNING
OFF
add ds1 UUCSS
125(d)
none Wrong
board
MINOR
ON
257(e)
65535
Control Channel Loop test
(#52)
MINOR
ON
test board UUCSS l r
20
513(f)
4352
4353
4355
4356
4358
TN2302 On board hardware
errors
MINOR
ON
769(g)
2-Way Transmission tests
(#1505 & 1506)
MINOR
OFF
1025(h)
Any
FPGA Query test (#1406)
MINOR
1281(i)
Any
TSI Health Query test
(#1406)
1538(j)
Any
Circuit pack is hyperactive
MINOR
ON
1793
Any
NIC Loss Of Signal
MIN/
WRN
2
2.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
test board UUCSS l r 2
2049(k)
Any
PPC Sanity Query test
(#1406)
2305(l)
Any
IP Address Update
2561(m)
Ping error
2817(n)
Any
Ethernet Hardware Query
test (#1406)
3073(o)
Any
Circuit pack reset test (#53)
3840,
3841(p)
Inconsistent downlink or
board error
3999(q)
Any
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...