Maintenance-Object Repair Procedures
555-233-143
8-1346
Issue 1 May 2002
Table 8-545.
Digital Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
1 – 20,
40987
None
WARNING
OFF
18 (b)
0
busyout port UUCSSpp
WARNING
OFF
re port UUCSSpp
257 (c)
40971
None
513 (d)
0
Station (Digital) Audits test
(#17)
WARNING
OFF
test port UUCSSpp sh r 6
767 (e)
40964
None
WARNING
OFF
769 (f)
40963,
40988
None
WARNING
OFF
1025 (g)
None
WARNING
OFF
1281
Any
Station (Digital) Audits test
(#17)
WARNING
OFF
test port UUCSSpp sh r 4
1537 (h)
40968
None
WARNING
OFF
2304 (i)
None
2305 (j)
32770,
40967
None
2817 (k)
Hyperactive
MINOR
OFF
3840 (l)
40965,
40989
None
3841 (m)
41029
None
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...