Alarms, Errors, and Troubleshooting
555-233-143
4-42
Issue 1 May 2002
■
State
should be
present
, indicating that A500 port board
insertion was successful. If
State
is
invalid
, then the A500
believes that the corresponding port board slot is empty or the port
board is not recognized.
It may be necessary to re-administer the A500 port boards. Refer to
the Cajun A500 Quick Reference for further information.
■
If
Admin Status
or
State
is incorrect, the links will not come up
between a non-IPSI-connected EPN and its controlling
IPSI-connected EPN.
TN230X
Did the TN230X come up correctly?
1. Review the LED conditions for the TN230X:
■
Do the TN230X LEDs (see
) indicate a
normal operational state (any of the following):
— Archangel mode in the EPN
— Standby in the EPN
2. If after board insertion or a demand reset:
■
Do the TN230X LEDs indicate that it is booting?
■
Do the TN230X LEDs indicate it is downloading its DSPs?
■
Do the TN230X LEDs indicate that board insertion has not yet
occurred?
■
Do the TN230X LEDs indicate a maintenance alarm?
3. Enter list configuration carrier cabinet carrier on the S8700
Multi-Connect SAT. See the following
(1b) and
(2a).
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...