background image

Station Automation COM600

Product Guide

Power Products

Summary of Contents for COM600 series

Page 1: ...Station Automation COM600 Product Guide Power Products...

Page 2: ...red trademark of ABB Group All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders 1 Description 3 2 Application 4 3 Paramete...

Page 3: ...ed communication protocols of substation devices For even greater con nectivity OPC data access and OPC alarms and events are supported to enable informa tion sharing and control with for example a di...

Page 4: ...or all communication protocols the gateway cross reference is done in the same way regardless of the protocol for example IEC 61850 8 1 or DNP3 COM600 can by using the optional web HMI requires Mozill...

Page 5: ...ng the optional serial card The four serial ports enable the connection and combination of different serial protocols For example 3 SPA 1 IEC 101 protocol or 2 SPA 1 IEC 103 1 IEC 101 protocol COM600...

Page 6: ...In depth analysis is enabled using ABB s Wineve software or any other commercially available disturbance record analyzer supporting the COMTRADE format Downloading of disturbance records requires use...

Page 7: ...ABB 7 Station Automation COM600 Product version 3 4 1MRS756764 B Fig 5 COM600 web HMI showing persisting and fleeting alarms Fig 6 COM600 Data historian...

Page 8: ...ff line functionality for engineering and diagnostics The logic process can be used for applica tions such as grouping of signals or tripping of all bus breakers if one of the breakers fails to clear...

Page 9: ...a human machine interface HMI and gateway functionality for a smooth integration Further COM600 offers connec tivity to ABB s Automation System 800xA and MicroSCADA by means of OPC or other com munic...

Page 10: ...ocol analyzers 12 Communication redundancy To maintain and improve the reliability of the communication network and the communi cation between the IEDs and COM600 IEC 62439 PRP parallel redundancy pro...

Page 11: ...able 3 Hardware Description Value Processor Intel Pentium M 1 6 GHz System memory 1 GB SDRAM Compact flash memory 8 GB industrial SSD Table 4 Interfaces Description Value Serial interfaces 3 x RS 232...

Page 12: ...Ripple in auxiliary DC voltage According to IEC 60255 11 12 f 2 x fn Power consumption According to CE EN 61010 Table 8 Insulation tests Description Standard Dielectric test According to IEC 60255 5...

Page 13: ...e Conducted radio frequency disturbance According to IEC 61000 4 6 and IEC 60255 22 6 10 V 80 ampl mod f 150 kHz 80 MHz Power frequency 50 Hz magnetic field According to IEC 61000 4 8 300 A m continuo...

Page 14: ...C Table 12 Mechanical tests Description Standard Vibration tests Vibration response test Vibration endurance test According to IEC 60068 2 6 and IEC 60255 21 1 f 10 150 Hz 0 035 mm 10 58 Hz 5 m s2 58...

Page 15: ...5 RoHS compliance Complies with the RoHS directive 2002 95 EC Seismic test biaxial multi frequency random seismic test According to IEC 60255 21 3 test method B 2 x gn in horizontal direction 1 x gn i...

Page 16: ...nunciator Unit SACO 16D3 Digital Annunciator Unit SACO 64D4 RE 500 series terminals Feeder Terminal REF 541 543 545 Transformer Terminal RET 541 543 545 Motor and Generator Terminal REM 543 545 Feeder...

Page 17: ...escriptions are used to automati cally configure the master communication of COM600 At project engineering SAB600 uses the potential of the IEC 61850 standard by sup porting the IEC 61850 based SCL Su...

Page 18: ...al communication cards PCI LON card PCLTA 20 plastic fibre 1 port P LON card PCLTA 20 glass fibre 1 port G Ethernet card RJ 45 10Base T 100Base TX 1000Base T 2 ports R Serial RS 232 RS 485 card 8 port...

Page 19: ...duct page The download area on the right hand side of the web page contains the latest product documentation such as user s guide opera tor s guide etc The selection tool on the web page helps you fin...

Page 20: ...358 10 22 11 Fax 358 10 22 41094 www abb com substationautomation ABB Inc Distribution Automation 655 Century Point Lake Mary Florida U S A Phone 407 732 2000 Fax 407 732 2335 www abb com substationau...

Reviews: