Maintenance-Object Repair Procedures
555-233-143
8-1842
Issue 1 May 2002
Table 8-704.
Test #1285 TDM Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
The port is in use.
1. Retry the command when the port is idle. You can force the port to the idle
state with the busyout port UUCSS command.
2. Escalate if the problem persists.
This command is destructive, tearing down every call and link using the port.
1002
ABORT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
1003
ABORT
No more tone receivers idle for use in this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. Repeat the test.
3. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
FAIL
Received tones do not match transmitted tones.
1. Retry command at 1-minute intervals up to 3 times.
2. If the problem persists, see
,
, and Tone Receiver repair procedures.
3. If the problem persists, reset the board (busyout board UUCSS, reset
board UUCSS, and release board UUCSS). Repeat the test.
4. If the problem persists, replace the circuit pack.
PASS
Port connections across the TDM bus function properly.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...