![Avaya S8700 Series Maintenance Manual Download Page 1010](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021010.webp)
Maintenance-Object Repair Procedures
555-233-143
8-288
Issue 1 May 2002
Packet Interface Loop Around Test (#598)
This nondestructive test checks the ATM-TRK circuit pack’s packet-bus interface.
The LANHO chip sends data through the bus and back to itself.
describes this test, substituting “CES mode” for “PNC mode.”
If the data received is consistent with the data sent, the test passes. The test
does not run if the specified EPN’s packet bus has a minor alarm or is out of
service.
ATM Board Reset (#1256)
This test is destructive.
This test checks the sanity of the angel processor using the Sanity and Control
Interface (SAKI) test (Common Port Board test, #53). It resets the circuit pack if
the SAKI test fails and runs the test again.The ATM Board Reset test passes if
SAKI can successfully reset and retest the board.
Before running the SAKI test, you must:
■
Move synchronization off the ATM-TRK circuit pack
■
Busyout the ATM-TRK circuit pack
The test aborts if the ATM-TRK circuit pack is supplying synchronization.
Table 8-124.
Packet Interface Loop Around Test (#598)
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Test request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test fails repeatedly, run reset board UUCSS.
3. If the test continues to fail, replace the ATM-TRK circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate needed system resources.
1. Retry the command up to 5 times at 1-minute intervals.
ANY
FAIL
Data packet not received correctly by the ATM Interface circuit pack.
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to fail, replace the ATM-TRK circuit pack.
PASS
The Packet Interface test passed.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...