Maintenance-Object Repair Procedures
555-233-143
8-372
Issue 1 May 2002
1187
ABORT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, BRI-PORT,
or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station via
the release station
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port PCSSpp command and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command and
run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board PPCSS
command and run the test again. If the error is present for BRI-SET
only, then release the circuit pack via the release port PPCSS
command and run the test again.
NOTE:
When you release the circuit pack, you release every port associated
with it. If certain ports still need to be busied out, use the busyout port
PCSSpp command to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2068
ABORT
The endpoint has rejected the switch sent application message. This indicates
that the endpoint does not support the ISDN-BRI Management and
Maintenance Procedure for Loop Back testing.
1. Use the change station extension command and change the MIMs
Supported field to n.
2069
ABORT
The endpoint has returned an error response to the application message sent
by the switch.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 8-156.
Test #627 BRI Remote Loop Back —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...