H323-SGRP (323 Signaling Group)
Issue 1 May 2002
8-893
555-233-143
H.323 Signaling Group Ping Test (#1387)
This test is Nondestructive.
This test is only run for those signaling groups that have an administered far-end
IP address. If the H.323 signaling group does not have an administered far-end
IP address, the test will abort.
The test determines the local C-LAN through which the signaling originates, and
the far-end terminating IP address. It then requests the local C-LAN to execute a
PING on the far-end address. If the PING is successful, the test passes; if the
ping is not successful, the test fails.
NOTE:
Multiple failures of this test can take the H.323 signaling group out of
service.
2000
ABORT
Response to the test was not received from the TN799DP C-LAN circuit pack
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports on the board are idle (amber LED is off). Reset the circuit pack by
issuing the busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2100
ABORT
The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The C-LAN ethernet port corresponding to the near-end address of the
SIG-GRP that is OOS has failed. Every session is down.
1. Execute test port UUCSSpp long and verify the result of the H.323
Signaling Group Ping test (#1387). If the test continues to fail, escalate the
problem. If the test passes wait for the sessions to come up.
PASS
The C-LAN ethernet port corresponding to the near-end address of the
SIG-GRP that is in service has passed this test. Every session on the ethernet
link is up.
Table 8-341.
Test #1386 CLAN Ethernet Status Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...