ANL-24-L (24-Port Analog Line)
Issue 1 May 2002
8-69
555-233-143
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to determine the service state of the
port.
3. If the port is active, wait until it is idle, and retry the command at 1-minute
intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018
ABORT
The test has been disabled via administration. The default for the
Test
field
on the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test #48, that can be
customer or terminal disturbing).
1. To enable the test for a particular station being tested, enter change
station extension and set the
Test?
field on the station from n to y.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Resolve TONE-PT errors.
2. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Issue the display port and the status station commands to determine
whether the station is idle. If the station is idle, issue the test port
command for this port.
2. If the test continues to fail, issue the busyout port and the release port
commands, and then retest.
3. If the test still fails, replace the board.
PASS
The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated by using other port tests and by examining
station, trunk, or external wiring.
Table 8-28.
Test #7 Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...