Maintenance-Object Repair Procedures
555-233-143
8-312
Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port
if one is available until the circuit pack can be replaced.
b. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling lead,
which is an off-board error. This error should only occur with loudspeaker
paging. If the trunk is being used for another application, check that the
administration is correct. Otherwise, check the wiring to the external
equipment connected to the Auxiliary Trunk and check the external
equipment.
c. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors.
d. Indicates the circuit pack has been removed or has been insane for more
than 11 minutes. To clear the error, reseat or replace the circuit pack.
Table 8-135.
Auxiliary Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate test’s
description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
57481
None
1(b)
57782
15(c)
Any
Audit Update test (#36)
18
0
busyout port UUCSSpp
WARNING
OFF
release port UUCSSpp
130(d)
None
WARNING
ON
test trunk grp/mbr sh
769(b)
57482
None
257
Hybrid/Conference
MINOR
WARNING
2
2.
Major or Minor alarms may be downgraded to Warning alarms based on the values used in the set options
command.
ON
test port UUCSSpp l r 3
Circuit test (#33)
513
NPE Crosstalk test (#6)
MINOR
WARNING
ON
test port UUCSSpp l r 3
1025
Diagnostic test —
Auxiliary Trunk test
(#114)
WARNING
ON
test port UUCSSpp sh r 3
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...