Maintenance-Object Repair Procedures
555-233-143
8-1356
Issue 1 May 2002
Notes:
a. Error Type - 1 — indicates that a PING test to the Remote Office has
failed, and a MINOR alarm has been raised.
The PING test verifies that a path to a registered Remote Office is good.
When this error is logged, as many as 26 endpoints (associated with that
Remote Office) and several H.323 signaling groups could be out of service.
b. Error Type - 257 — A Keep-Alive Timer is set for every registered endpoint
on the Remote Office. The switch expects keep-alive update information
within a certain time period, and if that time limit is exceeded, an error is
logged. The error is a log-only error, because there is no way to determine
which entity has failed.
However, the aux data associated with this error indicates whether the
endpoint that failed to respond was a DCP, Analog, or Signaling Group
type. Aux data with a value of:
■
1096 = Analog Line
■
1095 = DCP Line
■
6179 = H.323 Signaling Group
System Technician-Demanded Tests:
Descriptions and Error Codes
There are no demand tests for this MO, although the Remote Office can be
pinged using the ping ip | node command.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...